Sale!

Area Gamma Radiation Monitor

Original price was: ₹130,000.00.Current price is: ₹125,000.00. (GST @18% Extra)

The Area Gamma Radiation Monitor is a radiation monitoring device used for continuous gamma and X-ray dose rate monitoring in laboratories, nuclear facilities, radiotherapy departments and industrial radiological installations.

Area Gamma Monitor Overview

The Area Gamma Radiation Monitor from AETEC helps users monitor gamma radiation levels in working areas where continuous radiation safety monitoring is required. Additionally, this radiation monitoring device indicates dose rate on a clear display screen and provides audio-visual alarm indication when the radiation level crosses the preset alarm value.

Moreover, the system can monitor low gamma dose rate levels in radioisotope laboratories, radiotherapy departments, medical radiological areas, industrial radiography installations, atomic power stations, radiochemical plants and waste immobilization plants. Therefore, it supports radiation safety teams in maintaining safe working conditions.

In addition, the monitor can show dose rate, alarm status, configuration settings and system messages on a TFT display or LED display panel, depending on configuration. As a result, operators can read radiation status quickly and take action during alarm conditions.

Area Gamma Monitor Product Description

The Area Gamma Radiation Monitor provides continuous area radiation monitoring for gamma and X-ray radiation detection. It works as a gamma radiation detector and area radiation monitor for controlled radiation zones, laboratories and industrial radiation installations.

Additionally, the instrument measures dose rate in selected units such as mR/hr, µSv/hr, CPS and CPM. The default measuring range can be configured from 0.01 to 100 mR/hr or as per application requirement.

Moreover, the system uses a GM detector probe with energy compensation, pre-amplifier and suitable cable arrangement. Therefore, it can monitor radiation levels in the measurement area while the display unit remains in the operation room or control room when required.

Furthermore, the TFT display screen provides clear indication of measured value, alarm condition and configuration settings. The display panel can show NORMAL and ACTIVE alarm status through visual indication. Also, the screen can flash during alarm condition for better operator attention.

In addition, the Area Gamma Monitor supports RS485 and Ethernet communication for remote monitoring. It can support Modbus communication, network commands, alarm set point configuration, measured value reading, EHT value reading, acknowledge command and reset command.

Finally, the system provides a practical solution for users looking for radiation monitoring devices, gamma detector systems, radiation meter devices, monitor calibration support and network-based radiation monitoring solutions.

Key Features of Area Gamma Monitor

Firstly, the Area Gamma Monitor detects gamma and X-ray radiation in radiation-controlled areas.

Additionally, it provides continuous area radiation monitoring for laboratories and industrial installations.

Moreover, the system can show dose rate values on a TFT display, display screen or LED display panel.

Also, the monitor provides audio and visual alarm indication when the dose rate exceeds the preset value.

In addition, the unit supports settable alarm trip point, acknowledge control and reset control.

Furthermore, the monitor can support RS485 and RJ45 Ethernet communication for remote monitoring.

Therefore, users can connect the instrument with third-party software through Modbus communication as per configuration.

Also, the system supports data storage and recall with date and time stamping.

Finally, the monitor offers reliable operation for radiation safety, detector testing, control room monitoring and area surveillance applications.

Applications of Area Gamma Monitor

Firstly, use the Area Gamma Monitor for gamma radiation monitoring in radioisotope laboratories.

Additionally, use it in radiotherapy departments and medical radiological installations.

Moreover, industrial radiography areas can use this gamma radiation detector for workplace safety monitoring.

Also, atomic power stations can use the system for continuous area radiation monitoring.

In addition, radiochemical plants and waste immobilization plants can use it for radiation safety supervision.

Therefore, nuclear research laboratories can use this area radiation monitor for controlled zone monitoring.

Finally, GeM purchase managers, laboratory equipment companies and radiation safety departments can consider this product for institutional and industrial radiation monitoring requirements.

Technical Specifications

Parameter Specification
Product Name Area Gamma Radiation Monitor
Product Type Area Gamma Monitor / Area Radiation Monitor
Radiation Detected X-ray and gamma radiation
Detector GM probe with GMT, energy compensation filter and pre-amplifier
Detector Sensitivity 18 CPS/mR/hr approx.
Measurement Range 0.01 to 99.99 mR/hr / 0.01 to 100 mR/hr as per configuration
Energy Range 100 keV to 1.5 MeV
EHT Suitable EHT for GM detector
Accuracy ±15% throughout range with testing using Cobalt-60
Display TFT display / LED display / LCD display as per model configuration (Optional as per user)
Display Update Time Approx. 1 to 2 seconds
First Reading Within 5 seconds after power ON
Response Time Normal slow response and fast update during abrupt radiation change
Alarm Trip Point Settable
Visual Alarm Green indication for normal condition and flashing red indication for active alarm
Audio Alarm Loud audio tone for radiation alarm
Alarm Output Relay output with changeover contacts
Controls Acknowledge, reset, mains ON and EHT ON indication
External Control External reset and acknowledge provision
Recorder Output 4 to 20 mA output as per configuration
Data Storage 500 records with date and time stamping
Communication

(Optional)

RS485 and RJ45 Ethernet port
Network Protocol Modbus RS485 and Modbus TCP as per configuration
Power Supply 230V AC ±10%, 50 Hz
Power Resume Power resumes after power failure
Standard Designed as per applicable radiation monitoring requirements

Display and Communication Features

The monitor display screen helps users read dose rate, alarm status and configuration settings clearly. Additionally, the TFT screen or touch display can support easy operation in selected configurations.

Moreover, RS485 and Ethernet communication allow remote radiation monitoring from a control room or central monitoring software. Therefore, users can monitor multiple units in a networked environment.

In addition, the system can support display software, monitor software and configuration software as per application need. As a result, radiation safety teams can manage monitoring, alarm settings, address settings, date, time and data communication more efficiently.

Alarm and Safety Features

Firstly, the Area Gamma Monitor provides a settable alarm trip point for radiation safety control.

Additionally, it gives visual alarm indication through green and red status windows or LED clusters.

Moreover, the monitor screen can flash during active radiation alarm condition.

Also, the audio alarm provides a loud tone for operator attention.

In addition, relay output can interface with external alarm systems or control panels.

Therefore, the system supports reliable radiation alarm indication in laboratories, control rooms and radiation working areas.

FAQ About Area Gamma Monitor

Q1. What is an Area Gamma Monitor?

An Area Gamma Monitor is a radiation monitoring device used to monitor gamma radiation dose rate in a specific area.

Q2. Where can this monitor be used?

It can be used in radioisotope laboratories, radiotherapy departments, industrial radiography areas, atomic power stations, radiochemical plants and nuclear research laboratories.

Q3. What radiation does it detect?

The system detects X-ray and gamma radiation using a suitable GM detector probe.

Q4. Does the monitor have a display screen?

Yes, the monitor can include a TFT display, LED display panel or LCD display as per model configuration.

Q5. Does the monitor provide alarm indication?

Yes, it provides audio and visual alarm indication when the dose rate exceeds the preset alarm value.

Q6. Does it support remote communication?

Yes, the system can support RS485 and Ethernet communication for remote monitoring and network integration.

Q7. Can AETEC customize the Area Gamma Monitor?

Yes, AETEC can customize measurement range, detector configuration, display type, communication interface, alarm settings and software features as per client requirement.

Reviews

There are no reviews yet.

Be the first to review “Area Gamma Radiation Monitor”
Shopping Cart